2.4 PHYSICAL & TECHNICAL CHARACTERISTICS |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Greenblock Physical & Technical
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
5. Sound Transmission (STC) 55+ 6. Capillarity of EPS: None 7. Minimum Pouring Temperatures: to minus 4º F or minus 20º C 8. Production Method: Shape molding of Flame Retardant Expandable Polystyrene (EPS) by heat and steam with no additives using only raw EPS bead bearing National Evaluation Report (NER # 236.238.384 or 479) Certifications as required by all North American building code authorities. 9. Fire Resistant:
Expanded Polystyrene has a flash ignition temperature of 340º C (655º F), where pine is 224º C (400 º F). (Data from National Research Council of Canada) Self-ignition is 425º C (797º F). 10. Building Method: Stack units as if CMU’s. Secure straight and plumb with alignment hardware, fill with #5 or #6 slump, 3,000 psi concrete leaving units in place providing insulation, surface finish strapping & air/vapor barrier (resulting from EPS units filled solidly with concrete without any penetrations therein). 11. Pour Height 4’-10’ monolithic pours, no seams or joints. 12. R-Value (Thermal Resistance) in accordance w/ ASHRAE 2001Fundamentals Handbook & ASTM C177, 6” & 8” Core EPS R 22/4 inch core EPS R 17. The Thermal Performance of an assembled wall including calculations for EPS, Thermal Bridging, Thermal Mass & Air Tightness can be up to an R50 plus (+) wood frame equivalent depending upon local climatic conditions. 13. Water Vapor Test based on test result of 138.0 ng/Pa•s•m2 (201ng/ Pa•s•.m2, max.) 14. Water Absorption Test Result .35% by Volume. 15. Meets requirements for “Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation”, as a Type II Thermal Insulating Material per ASTM C578. 16. Greenblock Building Code Approvals:
17. Polypropylene Reinforcing webs meet requirements for plastic materials when tested in accordance with ASTM D 1929, UBC 26, ASTMD635, ASTMD2843. 18. Fastener withdrawal resistance in accordance with ASTM D 1761 and fastener lateral resistance testing. Finish Requirements:
20. Wind Speed rating: by P.E. design per ACI 318 and as required for specified use and as required by local code. 21. Seismic Rating: by P.E. design per ACI 318 and as required for specified use and as required by local code.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||